50WW1000 electrical steel is designed for efficient magnetic performance in motors and transformers. Its 0.5mm thickness and silicon-based composition reduce energy waste and heat buildup, making it a practical and economical choice for everyday electrical devices like appliances, industrial tools, and power equipment that require dependable operation at a reasonable cost.
Specification Parameters
| Standard of Electromagnetic Properties | ||||||
| Grade | Thickness (mm) | Max.Core loss P155 (W/kg) | Min.Magnetic Polarization J5000(T) | Min.Stacking Factor | Min.Number of Bends | Conventional Density (kg/dm) |
| 50WW1000 | 0.5 | 6 | 1.74 | 0.97 | 10 | 7.85 |
| Typical electromagnetic properties | ||||||||||
| Grade | Thickness (mm) | Conventional Density (kg/dm³) | Specific Total Loss(W/kg) | Magnetic Polarization(T) | ||||||
| P 0/50 | P15/50 | P0/60 | P 5/60 | J000 | J250 | 0 | J0000 | |||
| 50WW1000 | 0.5 | 7.85 | 2.44 | 5.32 | 3.09 | 6.85 | 1.57 | 1.67 | 1.74 | 1.85 |
| Typical mechanical properties | |||||||||||
| Grade | Thickness (mm) | Yield Strength (MPa) | TensileStrength (MPa) | Elongation (%) | Hardness | Number of Bends | Stacking Factor | ||||
| L | C | L | C | L | C | HV5 | L | C | |||
| 50WW1000 | 0.5 | 230 | 240 | 350 | 360 | 50 | 50 | 100 | ≥20 | ≥20 | 0.985 |